BUILDCARE INTERNATIONAL · ABU DHABI

Waterproofing Services in Abu Dhabi

Roof, wet-area and below-ground waterproofing enquiries for residential, commercial and industrial projects. Share your site photographs and specification with Buildcare International in Mussafah to discuss the required work and suitable material systems.

Roofs & terraces · Bathrooms & wet areas · Basements & foundations · Joint detailing

Illustrative waterproofing application.

Applications   /   Systems   /   Our products   /   FAQs   /   Get a quotation

START WITH THE SOURCE OF THE LEAK

A waterproofing system matched to your building

Visible water damage does not always identify the point where water enters. Roof outlets, upstands, penetrations, construction joints and damaged finishes all need consideration when defining waterproofing work.

Buildcare International handles waterproofing enquiries in Abu Dhabi with a focus on the application, substrate and specified system. Whether the requirement involves a roof coating, a sheet membrane or cementitious waterproofing, share the condition of the existing surface and the intended use so the scope can be assessed before materials are selected.

A complete proposal should identify preparation, repairs, primers, waterproofing layers, reinforcement, junction details and any required protection. Coating a visible damp patch alone may not address the underlying water path.

AREAS WE CAN DISCUSS

Waterproofing applications for Abu Dhabi projects

Roof & terrace waterproofing

Include the roof construction, existing coating or membrane, drainage, upstands and any equipment penetrations. Exposure, maintenance access and the final roof finish affect system selection.

Bathroom & wet-area waterproofing

Plan the waterproofing beneath the final finish, including wall-to-floor junctions, pipe penetrations and drains. The membrane, tile adhesive and finish must form a compatible specification.

Basement & foundation waterproofing

Confirm whether work is external or internal, the construction stage and the expected water exposure. Include construction joints, waterstops and the protection needed before subsequent works.

Balconies & podium areas

Review falls, door thresholds, outlets and movement joints alongside the waterproofing layer. Specify whether the finished area will be tiled, paved, landscaped or exposed.

CHOOSE THE COMPLETE BUILD-UP

Liquid, cementitious and membrane waterproofing systems

Liquid-applied waterproofing

Acrylic and polyurethane-based options can form continuous waterproofing layers over suitable prepared surfaces. Priming, reinforcement, coverage, curing and protection depend on the selected system. Confirm exposure and service conditions before selecting a coating.

Cementitious waterproofing

Cementitious coatings are options for specified concrete and masonry applications. Flexible and polymer-modified grades have different requirements; substrate condition, detailing, water pressure and the final covering need review against the manufacturer documentation.

Bituminous membranes & coatings

Sheet membranes and liquid bituminous coatings serve different roles. Specify the exact grade, primer, application method, laps, terminations and protection. A damp-proof coating should not be assumed to replace a specified waterproofing membrane.

Details matter: Corners, movement joints, outlets and penetrations often need dedicated tapes, reinforcement, sealants or waterstops. Products should be chosen within a documented, compatible system.

EXPLORE OUR PRODUCT RANGE

Waterproofing products from FIXX, Sika and Weber

Browse selected products with images from our catalogue. Each card links to the individual listing. Request the current technical data sheet, complete component requirements and availability for the exact product before confirming your order or application specification.

FIXX WATERPROOFING

FIXX AC 5000

Water-based acrylic protective coating. Enquire about FIXX AC 5000 for the specified exposed-surface waterproofing build-up.

FIXX WATERPROOFING

FIXX HYPOL 65

Hybrid polyurethane liquid waterproofing coating forming a flexible, seamless membrane.

FIXX WATERPROOFING

FIXX RBE

Rubber-modified bitumen emulsion for specified protective and damp-proof coating applications.

SIKA WATERPROOFING

Sikalastic®-152 AE

Two-component, fibre-reinforced flexible cementitious coating for concrete and masonry.

SIKA WATERPROOFING

SIKATOP SEAL 107

Cementitious waterproofing and protective slurry mortar for specified compatible substrates.

SIKA WATERPROOFING

SikaTop®-550 Seal

Two-component, acrylic-modified cementitious waterproofing and protective coating.

SIKA WATERPROOFING

SikaShield® E35 PE SA 4 mm

SBS-modified bituminous membrane. Confirm the exact grade, application method and protection details.

SIKA WATERPROOFING

SIKALASTIC 311

Cold-applied, pitch-modified polyurethane waterproofing membrane for specified applications.

WEBER WATERPROOFING

Weberdry 116 FX

Cementitious waterproofing system. Request the current technical data sheet and complete component requirements.

The products shown are alternatives for different applications and system components. They are not a single interchangeable waterproofing package. Stock, colours, packaging and lead times must be confirmed with your quotation.

Joint sealing, reinforcement and other specified materials

Include accessories in the BOQ so the enquiry covers the full build-up. Explore FIXX BAND AL PRO sealing tape, FIXX PU SEAL and Sika Joint Tape SA for their specified uses.

For consultant-nominated materials, send the exact product name and grade. You can also browse our Fosroc and Weber catalogues or send your Polybit, Soprema or AWAZEL material schedule for checking. Brand products should not be mixed or substituted without confirming system compatibility and approval requirements.

DEFINE THE WORK BEFORE APPLICATION

Waterproofing assessment and application process

01 · Review the site and water path

Record the area, substrate, leakage pattern and existing waterproofing. Review drainage, joints, access and the intended final finish.

02 · Prepare and detail the surface

Define cleaning, removal of failed materials and any substrate repairs. Set out corners, outlets, penetrations and joint treatments before the main waterproofing layer.

03 · Apply the approved build-up

Follow the selected system’s requirements for priming, membrane installation or coating layers, reinforcement and curing. Application conditions and coverage follow the manufacturer instructions.

04 · Inspect, test and protect

Agree inspection and any appropriate testing in the scope. Where flood testing is specified and suitable, plan its timing and method. Protect the finished waterproofing before follow-on work.

What affects waterproofing cost?

The area is only one part of the quotation. Existing membrane removal, surface repairs, access, penetrations, drainage details, system build-up and protective finishes can change the work required.

New construction and remedial leak treatment also need different information. Send the BOQ or specification where available, plus photographs and your required completion date. Inspection findings may be needed before the final scope is confirmed.

Information to include in your enquiry

  • Project name and site location in Abu Dhabi
  • Roof, wet area, basement or other application
  • Approximate area and existing surface finish
  • Photographs of leaks, drains, joints and damaged areas
  • Approved system, BOQ or consultant specification
  • Access restrictions and target completion date
  • Required testing, documents and warranty terms

YOUR QUESTIONS ANSWERED

Waterproofing services FAQs

Which waterproofing system is suitable for my roof?

The right system depends on the substrate, existing membrane or coating, drainage, exposure and final finish. Send photographs, area measurements and the specification so these factors can be reviewed before a product is selected.

Can waterproofing be applied over an existing membrane?

The existing layer needs assessment for adhesion, condition and compatibility. Damaged, weak or incompatible layers may require removal. An overlay should follow a documented system and preparation method.

Do you handle bathroom and wet-area waterproofing enquiries?

Yes. Share the location, floor and wall areas, substrate, drain details and planned tile finish. Include any project requirement for junction reinforcement, testing and protection before tiling.

Is waterproofing the same as damp proofing?

No. A damp-proof coating and a waterproofing membrane may have different intended exposure and performance requirements. The selected system must match the actual water conditions and the project specification.

How long does waterproofing take to complete?

Timing depends on preparation, repairs, system layers, application conditions, curing and any specified testing. Access restrictions and follow-on finishes also affect the programme.

Can I request a warranty?

Include your required warranty terms with the enquiry. Scope, duration, exclusions and any manufacturer involvement must be confirmed in writing for the selected system and agreed work.

Do you supply FIXX waterproofing products?

Yes. Our catalogue includes FIXX AC 5000, FIXX HYPOL 65 and FIXX RBE, along with selected sealing and joint accessories. Send the exact product, quantity and required date to check availability and pricing.

Can you quote from drawings or a BOQ?

Yes. Send the drawings, specified materials, quantities and location. State whether your enquiry is for materials, application work or both, so the team can confirm the available scope and quotation requirements.

LET’S DISCUSS YOUR REQUIREMENT

Request a waterproofing quotation in Abu Dhabi

Contact Buildcare International in Mussafah MW5 with your site photographs, approximate area and project specification. Tell us whether you need materials, application work or both so we can confirm the scope and next steps.

Buildcare International
Mussafah MW5, Abu Dhabi, UAE
02 448 1915 · info@buildcareint.com

BUILT ON TRUST. DELIVERED WITH CARE.